Added Electric Pump energy usage config value, also fixed a few bugs with the new Gas-Burning Generator

This commit is contained in:
Aidan C. Brady committed 2014-06-10 12:24:44 +02:00
1 parent d7fdc3a243
commit 8685664d51
23 files changed
+110 -87

No files matched your search

@@ -328,6 +328,7 @@ public class Mekanism
public static double purificationChamberUsage;
public static double energizedSmelterUsage;
public static double digitalMinerUsage;
public static double electricPumpUsage;
public static double rotaryCondensentratorUsage;
public static double oxidationChamberUsage;
public static double chemicalInfuserUsage;