package crazypants.enderio; import java.io.File; import java.io.IOException; import net.minecraftforge.common.Configuration; import org.apache.commons.io.FileUtils; import cpw.mods.fml.common.event.FMLPreInitializationEvent; import crazypants.vecmath.VecmathUtil; public final class Config { static int BID = 700; static int IID = 8524; public static final double DEFAULT_CONDUIT_SCALE = 0.2; public static boolean useAlternateBinderRecipe; public static boolean useAlternateTesseractModel; public static boolean photovoltaicCellEnabled = true; public static double conduitScale = DEFAULT_CONDUIT_SCALE; public static int numConduitsPerRecipe = 8; public static double transceiverEnergyLoss = 0.1; public static double transceiverUpkeepCost = 0.25; public static double transceiverBucketTransmissionCost = 1; public static int transceiverMaxIO = 256; public static File configDirectory; public static boolean useHardRecipes = false; public static boolean detailedPowerTrackingEnabled = false; public static double maxPhotovoltaicOutput = 1.0; public static boolean useSneakMouseWheelYetaWrench = true; public static boolean useSneakRightClickYetaWrench = false; public static boolean useRfAsDefault = true; public static boolean itemConduitUsePhyscialDistance = false; public static int advancedFluidConduitExtractRate = 100; public static int advancedFluidConduitMaxIoRate = 400; public static int fluidConduitExtractRate = 50; public static int fluidConduitMaxIoRate = 200; public static void load(FMLPreInitializationEvent event) { configDirectory = new File(event.getModConfigurationDirectory(), "enderio"); if(!configDirectory.exists()) { configDirectory.mkdir(); } File deprecatedFile = event.getSuggestedConfigurationFile(); File configFile = new File(configDirectory, "EnderIO.cfg"); if(deprecatedFile.exists()) { try { FileUtils.moveFile(deprecatedFile, configFile); } catch (IOException e) { Log.warn("Could not move old config file to new directory: " + e); } } Configuration cfg = new Configuration(configFile); try { cfg.load(); Config.processConfig(cfg); } catch (Exception e) { Log.error("EnderIO has a problem loading it's configuration"); } finally { if(cfg.hasChanged()) { cfg.save(); } } } public static void processConfig(Configuration config) { for (ModObject e : ModObject.values()) { e.load(config); } useRfAsDefault = config.get("Settings", "displayPowerAsRedstoneFlux", useRfAsDefault, "If true, all power is displayed in RF, otherwise MJ is used.") .getBoolean(useRfAsDefault); useHardRecipes = config.get("Settings", "useHardRecipes", useHardRecipes, "When enabled machines cost significantly more.") .getBoolean(useHardRecipes); numConduitsPerRecipe = config.get("Settings", "numConduitsPerRecipe", numConduitsPerRecipe, "The number of conduits crafted per recipe.").getInt(numConduitsPerRecipe); photovoltaicCellEnabled = config.get("Settings", "photovoltaicCellEnabled", photovoltaicCellEnabled, "If set to false Photovoltaic Cells will not be craftable.") .getBoolean(photovoltaicCellEnabled); maxPhotovoltaicOutput = config.get("Settings", "maxPhotovoltaicOutput", maxPhotovoltaicOutput, "Maximum output in MJ/t of the Photovoltaic Panels.").getDouble(maxPhotovoltaicOutput); useAlternateBinderRecipe = config.get("Settings", "useAlternateBinderRecipe", false, "Create conduit binder in crafting table instead of furnace") .getBoolean(useAlternateBinderRecipe); conduitScale = config.get("Settings", "conduitScale", DEFAULT_CONDUIT_SCALE, "Valid values are between 0-1, smallest conduits at 0, largest at 1.\n" + "In SMP, all clients must be using the same value as the server.").getDouble(DEFAULT_CONDUIT_SCALE); conduitScale = VecmathUtil.clamp(conduitScale, 0, 1); fluidConduitExtractRate = config.get("Settings", "fluidConduitExtractRate", fluidConduitExtractRate, "Number of millibuckects per tick extract by a fluid conduits auto extract..").getInt(fluidConduitExtractRate); fluidConduitMaxIoRate = config.get("Settings", "fluidConduitMaxIoRate", fluidConduitMaxIoRate, "Number of millibuckects per tick that can pass through a single connection to a fluid conduit.").getInt(fluidConduitMaxIoRate); advancedFluidConduitExtractRate = config.get("Settings", "advancedFluidConduitExtractRate", advancedFluidConduitExtractRate, "Number of millibuckects per tick extract by advanced fluid conduits auto extract..").getInt(advancedFluidConduitExtractRate); advancedFluidConduitMaxIoRate = config.get("Settings", "advancedFluidConduitMaxIoRate", advancedFluidConduitMaxIoRate, "Number of millibuckects per tick that can pass through a single connection to an advanced fluid conduit.").getInt(advancedFluidConduitMaxIoRate); useAlternateTesseractModel = config.get("Settings", "useAlternateTransceiverModel", useAlternateTesseractModel, "Use TheKazador's alternatice model for the Dimensional Transceiver") .getBoolean(false); transceiverEnergyLoss = config.get("Settings", "transceiverEnergyLoss", transceiverEnergyLoss, "Amount of energy lost when transfered by Dimensional Transceiver 0 is no loss, 1 is 100% loss").getDouble(transceiverEnergyLoss); transceiverUpkeepCost = config.get("Settings", "transceiverUpkeepCost", transceiverUpkeepCost, "Number of MJ/t required to keep a Dimensional Transceiver connection open").getDouble(transceiverUpkeepCost); transceiverMaxIO = config.get("Settings", "transceiverMaxIO", transceiverMaxIO, "Maximum MJ/t sent and recieved by a Dimensional Transceiver per tick. Input and output limits are not cumulative").getInt(transceiverMaxIO); transceiverBucketTransmissionCost = config.get("Settings", "transceiverBucketTransmissionCost", transceiverBucketTransmissionCost, "The cost in MJ of trasporting a bucket of fluid via a Dimensional Transceiver.").getDouble(transceiverBucketTransmissionCost); detailedPowerTrackingEnabled = config .get( "Settings", "perInterfacePowerTrackingEnabled", detailedPowerTrackingEnabled, "Enable per tick sampling on individual power inputs and outputs. This allows slightly more detailed messages from the MJ Reader but has a negative impact on server performance.") .getBoolean(detailedPowerTrackingEnabled); useSneakMouseWheelYetaWrench = config.get("Settings", "useSneakMouseWheelYetaWrench", useSneakMouseWheelYetaWrench, "If true, shift-mouse wheel will change the conduit display mode when the YetaWrench is eqipped.") .getBoolean(useSneakMouseWheelYetaWrench); useSneakRightClickYetaWrench = config.get("Settings", "useSneakRightClickYetaWrench", useSneakRightClickYetaWrench, "If true, shift-clicking the YetaWrench on a null or non wrenchable object will change the conduit display mode.") .getBoolean(useSneakRightClickYetaWrench); itemConduitUsePhyscialDistance = config.get("Settings", "itemConduitUsePhyscialDistance", itemConduitUsePhyscialDistance, "If true, " + "'line of sight' distance rather than conduit path distance is used to calculate priorities.") .getBoolean(itemConduitUsePhyscialDistance); itemConduitUsePhyscialDistance = config.get("Settings", "itemConduitUsePhyscialDistance", itemConduitUsePhyscialDistance, "If true, " + "'line of sight' distance rather than conduit path distance is used to calculate priorities.") .getBoolean(itemConduitUsePhyscialDistance); if(!useSneakMouseWheelYetaWrench && !useSneakRightClickYetaWrench) { Log.warn("Both useSneakMouseWheelYetaWrench and useSneakRightClickYetaWrench are set to false. Enabling mouse wheel."); useSneakMouseWheelYetaWrench = true; } } private Config() { } }