mirror of
https://github.com/GTNewHorizons/EnderIO.git
synced 2026-11-25 06:24:24 +00:00
more moving.
This commit is contained in:
1 parent
ce486c0540
commit
bef5f6193e
510 files changed
No files matched your search
@@ -0,0 +1,257 @@
|
||||
package crazypants.enderio;
|
||||
|
||||
import cpw.mods.fml.common.event.FMLPreInitializationEvent;
|
||||
import crazypants.vecmath.VecmathUtil;
|
||||
import net.minecraftforge.common.config.Configuration;
|
||||
import org.apache.commons.io.FileUtils;
|
||||
|
||||
import java.io.File;
|
||||
import java.io.IOException;
|
||||
|
||||
public final class Config {
|
||||
|
||||
static int BID = 700;
|
||||
static int IID = 8524;
|
||||
|
||||
public static final double DEFAULT_CONDUIT_SCALE = 0.2;
|
||||
|
||||
public static boolean useAlternateBinderRecipe;
|
||||
|
||||
public static boolean useAlternateTesseractModel;
|
||||
|
||||
public static boolean photovoltaicCellEnabled = true;
|
||||
|
||||
public static double conduitScale = DEFAULT_CONDUIT_SCALE;
|
||||
|
||||
public static int numConduitsPerRecipe = 8;
|
||||
|
||||
public static double transceiverEnergyLoss = 0.1;
|
||||
|
||||
public static double transceiverUpkeepCost = 0.25;
|
||||
|
||||
public static double transceiverBucketTransmissionCost = 1;
|
||||
|
||||
public static int transceiverMaxIO = 256;
|
||||
|
||||
public static File configDirectory;
|
||||
|
||||
public static boolean useHardRecipes = false;
|
||||
|
||||
public static boolean detailedPowerTrackingEnabled = false;
|
||||
|
||||
public static double maxPhotovoltaicOutput = 1.0;
|
||||
|
||||
public static boolean useSneakMouseWheelYetaWrench = true;
|
||||
|
||||
public static boolean useSneakRightClickYetaWrench = false;
|
||||
|
||||
public static boolean useRfAsDefault = true;
|
||||
|
||||
public static boolean itemConduitUsePhyscialDistance = false;
|
||||
|
||||
public static int advancedFluidConduitExtractRate = 100;
|
||||
|
||||
public static int advancedFluidConduitMaxIoRate = 400;
|
||||
|
||||
public static int fluidConduitExtractRate = 50;
|
||||
|
||||
public static int fluidConduitMaxIoRate = 200;
|
||||
|
||||
public static boolean renderCapBankGauge = true;
|
||||
|
||||
public static boolean renderCapBankGaugeBackground = true;
|
||||
|
||||
public static boolean renderCapBankGaugeLevel = true;
|
||||
|
||||
public static boolean updateLightingWhenHidingFacades = false;
|
||||
|
||||
public static boolean travelAnchorEnabled = true;
|
||||
public static int travelAnchorMaxDistance = 48;
|
||||
|
||||
public static int travelStaffMaxDistance = 96;
|
||||
public static float travelStaffPowerPerBlock = 10;
|
||||
public static int travelStaffMaxStoredPower = 25000;
|
||||
public static int travelStaffMaxPowerIo = 500;
|
||||
public static int travelStaffMaxBlinkDistance = 8;
|
||||
public static int travelStaffBlinkPauseTicks = 10;
|
||||
|
||||
public static boolean travelStaffEnabled = true;
|
||||
public static boolean travelStaffBlinkEnabled = true;
|
||||
public static boolean travelStaffBlinkThroughSolidBlocksEnabled = true;
|
||||
public static boolean travelStaffBlinkThroughClearBlocksEnabled = true;
|
||||
|
||||
public static int enderIoRange = 8;
|
||||
public static boolean enderIoMeAccessEnabled = true;
|
||||
|
||||
public static void load(FMLPreInitializationEvent event) {
|
||||
configDirectory = new File(event.getModConfigurationDirectory(), "enderio");
|
||||
if(!configDirectory.exists()) {
|
||||
configDirectory.mkdir();
|
||||
}
|
||||
|
||||
File deprecatedFile = event.getSuggestedConfigurationFile();
|
||||
|
||||
File configFile = new File(configDirectory, "EnderIO.cfg");
|
||||
if(deprecatedFile.exists()) {
|
||||
try {
|
||||
FileUtils.moveFile(deprecatedFile, configFile);
|
||||
} catch (IOException e) {
|
||||
Log.warn("Could not move old config file to new directory: " + e);
|
||||
}
|
||||
}
|
||||
|
||||
Configuration cfg = new Configuration(configFile);
|
||||
try {
|
||||
cfg.load();
|
||||
Config.processConfig(cfg);
|
||||
} catch (Exception e) {
|
||||
Log.error("EnderIO has a problem loading it's configuration");
|
||||
} finally {
|
||||
if(cfg.hasChanged()) {
|
||||
cfg.save();
|
||||
}
|
||||
}
|
||||
}
|
||||
|
||||
public static void processConfig(Configuration config) {
|
||||
useRfAsDefault = config.get("Settings", "displayPowerAsRedstoneFlux", useRfAsDefault, "If true, all power is displayed in RF, otherwise MJ is used.")
|
||||
.getBoolean(useRfAsDefault);
|
||||
|
||||
useHardRecipes = config.get("Settings", "useHardRecipes", useHardRecipes, "When enabled machines cost significantly more.")
|
||||
.getBoolean(useHardRecipes);
|
||||
|
||||
numConduitsPerRecipe = config.get("Settings", "numConduitsPerRecipe", numConduitsPerRecipe,
|
||||
"The number of conduits crafted per recipe.").getInt(numConduitsPerRecipe);
|
||||
|
||||
photovoltaicCellEnabled = config.get("Settings", "photovoltaicCellEnabled", photovoltaicCellEnabled,
|
||||
"If set to false Photovoltaic Cells will not be craftable.")
|
||||
.getBoolean(photovoltaicCellEnabled);
|
||||
|
||||
maxPhotovoltaicOutput = config.get("Settings", "maxPhotovoltaicOutput", maxPhotovoltaicOutput,
|
||||
"Maximum output in MJ/t of the Photovoltaic Panels.").getDouble(maxPhotovoltaicOutput);
|
||||
|
||||
useAlternateBinderRecipe = config.get("Settings", "useAlternateBinderRecipe", false, "Create conduit binder in crafting table instead of furnace")
|
||||
.getBoolean(useAlternateBinderRecipe);
|
||||
|
||||
conduitScale = config.get("Settings", "conduitScale", DEFAULT_CONDUIT_SCALE,
|
||||
"Valid values are between 0-1, smallest conduits at 0, largest at 1.\n" +
|
||||
"In SMP, all clients must be using the same value as the server.").getDouble(DEFAULT_CONDUIT_SCALE);
|
||||
conduitScale = VecmathUtil.clamp(conduitScale, 0, 1);
|
||||
|
||||
fluidConduitExtractRate = config.get("Settings", "fluidConduitExtractRate", fluidConduitExtractRate,
|
||||
"Number of millibuckects per tick extract by a fluid conduits auto extract..").getInt(fluidConduitExtractRate);
|
||||
|
||||
fluidConduitMaxIoRate = config.get("Settings", "fluidConduitMaxIoRate", fluidConduitMaxIoRate,
|
||||
"Number of millibuckects per tick that can pass through a single connection to a fluid conduit.").getInt(fluidConduitMaxIoRate);
|
||||
|
||||
advancedFluidConduitExtractRate = config.get("Settings", "advancedFluidConduitExtractRate", advancedFluidConduitExtractRate,
|
||||
"Number of millibuckects per tick extract by advanced fluid conduits auto extract..").getInt(advancedFluidConduitExtractRate);
|
||||
|
||||
advancedFluidConduitMaxIoRate = config.get("Settings", "advancedFluidConduitMaxIoRate", advancedFluidConduitMaxIoRate,
|
||||
"Number of millibuckects per tick that can pass through a single connection to an advanced fluid conduit.").getInt(advancedFluidConduitMaxIoRate);
|
||||
|
||||
useAlternateTesseractModel = config.get("Settings", "useAlternateTransceiverModel", useAlternateTesseractModel,
|
||||
"Use TheKazador's alternatice model for the Dimensional Transceiver")
|
||||
.getBoolean(false);
|
||||
transceiverEnergyLoss = config.get("Settings", "transceiverEnergyLoss", transceiverEnergyLoss,
|
||||
"Amount of energy lost when transfered by Dimensional Transceiver 0 is no loss, 1 is 100% loss").getDouble(transceiverEnergyLoss);
|
||||
transceiverUpkeepCost = config.get("Settings", "transceiverUpkeepCost", transceiverUpkeepCost,
|
||||
"Number of MJ/t required to keep a Dimensional Transceiver connection open").getDouble(transceiverUpkeepCost);
|
||||
transceiverMaxIO = config.get("Settings", "transceiverMaxIO", transceiverMaxIO,
|
||||
"Maximum MJ/t sent and recieved by a Dimensional Transceiver per tick. Input and output limits are not cumulative").getInt(transceiverMaxIO);
|
||||
transceiverBucketTransmissionCost = config.get("Settings", "transceiverBucketTransmissionCost", transceiverBucketTransmissionCost,
|
||||
"The cost in MJ of trasporting a bucket of fluid via a Dimensional Transceiver.").getDouble(transceiverBucketTransmissionCost);
|
||||
|
||||
detailedPowerTrackingEnabled = config
|
||||
.get(
|
||||
"Settings",
|
||||
"perInterfacePowerTrackingEnabled",
|
||||
detailedPowerTrackingEnabled,
|
||||
"Enable per tick sampling on individual power inputs and outputs. This allows slightly more detailed messages from the MJ Reader but has a negative impact on server performance.")
|
||||
.getBoolean(detailedPowerTrackingEnabled);
|
||||
|
||||
useSneakMouseWheelYetaWrench = config.get("Settings", "useSneakMouseWheelYetaWrench", useSneakMouseWheelYetaWrench,
|
||||
"If true, shift-mouse wheel will change the conduit display mode when the YetaWrench is eqipped.")
|
||||
.getBoolean(useSneakMouseWheelYetaWrench);
|
||||
|
||||
useSneakRightClickYetaWrench = config.get("Settings", "useSneakRightClickYetaWrench", useSneakRightClickYetaWrench,
|
||||
"If true, shift-clicking the YetaWrench on a null or non wrenchable object will change the conduit display mode.")
|
||||
.getBoolean(useSneakRightClickYetaWrench);
|
||||
|
||||
itemConduitUsePhyscialDistance = config.get("Settings", "itemConduitUsePhyscialDistance", itemConduitUsePhyscialDistance, "If true, " +
|
||||
"'line of sight' distance rather than conduit path distance is used to calculate priorities.")
|
||||
.getBoolean(itemConduitUsePhyscialDistance);
|
||||
|
||||
itemConduitUsePhyscialDistance = config.get("Settings", "itemConduitUsePhyscialDistance", itemConduitUsePhyscialDistance, "If true, " +
|
||||
"'line of sight' distance rather than conduit path distance is used to calculate priorities.")
|
||||
.getBoolean(itemConduitUsePhyscialDistance);
|
||||
|
||||
if(!useSneakMouseWheelYetaWrench && !useSneakRightClickYetaWrench) {
|
||||
Log.warn("Both useSneakMouseWheelYetaWrench and useSneakRightClickYetaWrench are set to false. Enabling mouse wheel.");
|
||||
useSneakMouseWheelYetaWrench = true;
|
||||
}
|
||||
|
||||
travelAnchorEnabled = config.get("Settings", "travelAnchorEnabled", travelAnchorEnabled,
|
||||
"When set to false the travel anchor will not be craftable.").getBoolean(travelAnchorEnabled);
|
||||
|
||||
travelAnchorMaxDistance = config.get("Settings", "travelAnchorMaxDistance", travelAnchorMaxDistance,
|
||||
"Maximum number of blocks that can be traveled from one travel anchor to another.").getInt(travelAnchorMaxDistance);
|
||||
|
||||
travelStaffMaxDistance = config.get("Settings", "travelStaffMaxDistance", travelStaffMaxDistance,
|
||||
"Maximum number of blocks that can be traveled using the Staff of the Traveling.").getInt(travelStaffMaxDistance);
|
||||
travelStaffPowerPerBlock = (float) config.get("Settings", "travelStaffPowerPerBlock", travelStaffPowerPerBlock,
|
||||
"Number of MJ required per block travelled using the Staff of the Traveling.").getDouble(travelStaffPowerPerBlock);
|
||||
|
||||
travelStaffMaxStoredPower = config.get("Settings", "travelStaffMaxStoredPower", travelStaffMaxStoredPower,
|
||||
"Maximum number of MJ that can be stored using in the Staff of the Traveling.").getInt(travelStaffMaxStoredPower);
|
||||
|
||||
travelStaffMaxPowerIo = config.get("Settings", "travelStaffMaxPowerIo", travelStaffMaxPowerIo,
|
||||
"Maximum number of MJ that the Staff of the Traveling can be charged per tick.").getInt(travelStaffMaxPowerIo);
|
||||
|
||||
travelStaffMaxBlinkDistance = config.get("Settings", "travelStaffMaxBlinkDistance", travelStaffMaxBlinkDistance,
|
||||
"Max number of blocks teleported when shift clicking the staff.").getInt(travelStaffMaxBlinkDistance);
|
||||
|
||||
travelStaffBlinkPauseTicks = config.get("Settings", "travelStaffBlinkPauseTicks", travelStaffBlinkPauseTicks,
|
||||
"Minimum number of ticks between 'blinks'. Values of 10 or less allow a limited sort of flight.").getInt(travelStaffBlinkPauseTicks);
|
||||
|
||||
travelStaffEnabled = config.get("Settings", "travelStaffEnabled", travelAnchorEnabled,
|
||||
"If set to false the travel staff will not be craftable.").getBoolean(travelStaffEnabled);
|
||||
travelStaffBlinkEnabled = config.get("Settings", "travelStaffBlinkEnabled", travelStaffBlinkEnabled,
|
||||
"If set to false the travel staff can not be used to shift-right click teleport, or blink.").getBoolean(travelStaffBlinkEnabled);
|
||||
travelStaffBlinkThroughSolidBlocksEnabled = config.get("Settings", "travelStaffBlinkThroughSolidBlocksEnabled", travelStaffBlinkThroughSolidBlocksEnabled,
|
||||
"If set to false the travel staff can be used to blink through any block.").getBoolean(travelStaffBlinkThroughSolidBlocksEnabled);
|
||||
travelStaffBlinkThroughClearBlocksEnabled = config
|
||||
.get("Settings", "travelStaffBlinkThroughClearBlocksEnabled", travelStaffBlinkThroughClearBlocksEnabled,
|
||||
"If travelStaffBlinkThroughSolidBlocksEnabled is set to false and this is true, the travel " +
|
||||
"staff can only be used to blink through transparent or partial blocks (e.g. torches). " +
|
||||
"If both are false, only air blocks may be teleported through.")
|
||||
.getBoolean(travelStaffBlinkThroughClearBlocksEnabled);
|
||||
|
||||
enderIoRange = config.get("Settings", "enderIoRange", enderIoRange,
|
||||
"Range accessable (in blocks) when using the Ender IO.").getInt(enderIoRange);
|
||||
|
||||
enderIoMeAccessEnabled = config.get("Settings", "enderIoMeAccessEnabled", enderIoMeAccessEnabled,
|
||||
"If fasle, you will not be able to access a ME acess or crafting terminal using the Ender IO.").getBoolean(enderIoMeAccessEnabled);
|
||||
|
||||
updateLightingWhenHidingFacades = config.get("Settings", "updateLightingWhenHidingFacades", updateLightingWhenHidingFacades,
|
||||
"When true, correct lighting is recalculated (client side) for conduit bundles when transitioning to"
|
||||
+ " from being hidden behind a facade. This produces "
|
||||
+ "better quality rendering but can result in frame stutters when switching to/from a wrench.")
|
||||
.getBoolean(updateLightingWhenHidingFacades);
|
||||
|
||||
//TODO: Debug
|
||||
renderCapBankGauge = config.get("Debug", "renderCapBankGauge", renderCapBankGauge, "If not true capacitor banks will not render the level gauge at all.")
|
||||
.getBoolean(renderCapBankGauge);
|
||||
renderCapBankGaugeBackground = config.get("Debug", "renderCapBankGaugeBackground", renderCapBankGaugeBackground,
|
||||
"If not true capacitor banks will not render the level gauge background.")
|
||||
.getBoolean(renderCapBankGaugeBackground);
|
||||
renderCapBankGaugeLevel = config.get("Debug", "renderCapBankGaugeLevel", renderCapBankGaugeLevel,
|
||||
"If not true capacitor banks will not render the level on the gauge.")
|
||||
.getBoolean(renderCapBankGaugeLevel);
|
||||
|
||||
}
|
||||
|
||||
private Config() {
|
||||
}
|
||||
|
||||
}
|
||||
Reference in new issue
Block a user